A23L-05
Near Real-Time Automatic Data Quality Controls for the AERONET Version 3 Database: An Introduction to the New Level 1.5V Aerosol Optical Depth Data Product

Tuesday, 15 December 2015: 14:40
3006 (Moscone West)
David Matthew Giles1,2, Brent N Holben2, Alexander Smirnov1,2, Thomas F Eck2,3, Ilya Slutsker1,2, Mikhail G Sorokin1,2, Fred Espenak2, Joel Schafer1,2 and Alexander Sinyuk1,2, (1)Science Systems and Applications, Inc., Lanham, MD, United States, (2)NASA Goddard Space Flight Center, Greenbelt, MD, United States, (3)Universities Space Research Association Greenbelt, Greenbelt, MD, United States
Abstract:
The Aerosol Robotic Network (AERONET) has provided a database of aerosol optical depth (AOD) measured by surface-based Sun/sky radiometers for over 20 years. AERONET provides unscreened (Level 1.0) and automatically cloud cleared (Level 1.5) AOD in near real-time (NRT), while manually inspected quality assured (Level 2.0) AOD are available after instrument field deployment (Smirnov et al., 2000). The growing need for NRT quality controlled aerosol data has become increasingly important. Applications of AERONET NRT data include the satellite evaluation (e.g., MODIS, VIIRS, MISR, OMI), data synergism (e.g., MPLNET), verification of aerosol forecast models and reanalysis (e.g., GOCART, ICAP, NAAPS, MERRA), input to meteorological models (e.g., NCEP, ECMWF), and field campaign support (e.g., KORUS-AQ, ORACLES). In response to user needs for quality controlled NRT data sets, the new Version 3 (V3) Level 1.5V product was developed with similar quality controls as those applied by hand to the Version 2 (V2) Level 2.0 data set.

The AERONET cloud screened (Level 1.5) NRT AOD database can be significantly impacted by data anomalies. The most significant data anomalies include AOD diurnal dependence due to contamination or obstruction of the sensor head windows, anomalous AOD spectral dependence due to problems with filter degradation, instrument gains, or non-linear changes in calibration, and abnormal changes in temperature sensitive wavelengths (e.g., 1020nm) in response to anomalous sensor head temperatures. Other less common AOD anomalies result from loose filters, uncorrected clock shifts, connection and electronic issues, and various solar eclipse episodes. Automatic quality control algorithms are applied to the new V3 Level 1.5 database to remove NRT AOD anomalies and produce the new AERONET V3 Level 1.5V AOD product. Results of the quality control algorithms are presented and the V3 Level 1.5V AOD database is compared to the V2 Level 2.0 AOD database.